Features

wireless modbus relay remote controlled relay act as modbus RTU slave very long range, no hopping up to 8 relays per network protected private connection multiple addressable groups

Features

wireless modbus relay remote controlled relay act as modbus RTU slave very long range, no hopping up to 8 relays per network protected private connection multiple addressable groups

Technical specifications
Modbus
Address range 200..207
Relay mapping coil 1 (start address 00h)
Data bits & parity 8n1
Supported functions 01 – read coils
05 – write single coil
15 – write multiple coils
Relay output
Nominal rating 10A 250Vac (NO), 3A 250Vac (NC)
(resistive) 5A 30Vdc (NO), 3A 30Vdc (NC)
Radio
Frequency band ISM 868MHz (EU)
Subband L 866.8MHz, 25mW, 1% utility
Modulation FSK 38.4kbps 80kHz bandwidth
Listen before talk yes, delay limited to 20ms
Group address 32-bit, automatically generated
Connection time 10s power-on to network ready
Message delay 5ms from tx start to relay on
Output power 25mW
Operating range 3..300m with optical visibility
General
Power supply 230V, 50..60Hz, 1W
Terminals 0.25..1.5mm2
Operating conditions -20..+50°C, 0..85% rh nc
Storage temperature -40..+85°C
Dimensions 93x45x27mm, 86mm antenna
Weight 100g
Degree of protection IP20
Standards EN60730-1, EN300-220-2
Order Code
WR-1